PacifiCorp replaces string wound filters with Pall pleated media filter for ACC condensate

In 2011 the Wyodak plant of Pacific Corp replaced its air cooled condenser for a 365 MW coal fired boiler. It also upgraded to 20 micron filtration elements in a new full flow condensate filter. The higher efficiency filter has reduced iron deposition. More efficient 6 micron filter elements were also available but the additional cost seemed to outweigh the advantages.

Revision Date:  8/29/2016

Tags:  221118 - Other Electric Power , PacifiCorp, Pall Corporation, Cartridge Filter, Cooling


Wartsila power plants can operate with multi fuels

Wärtsilä’s power plants enable the transition to a sustainable, reliable and affordable power system. The main cornerstones are very high energy efficiency, outstanding operational flexibility, and multi-fuel operation. The applications range from stationary and floating base- load power plants to dynamic grid stability and peak load services, balancing large input fluctuations of wind and solar power, as well as serving a wide variety of industrial self-generation needs. This brochure outlines the capabilities and designs to handle gaseous and liquid fuels as well as multiple fuels. Multi-fuel power plants make power generation more reliable by being able to adapt to any situations that may occur regarding fuel availability or affordability. They can even switch fuels while running, for example changing to liq- uid fuel mode if the gas supply is suddenly interrupted. This capability provides 24/7 security of supply, hedge against fuel price increases and preparation for future fuel infrastructure development. Wärtsilä’s multi-fuel power plants can run in the following operations…

Revision Date:  8/1/2016

Tags:  221112 - Fossil Fuel 化石燃料, 221112 - Fossil Fuel 化石燃料, 221112 - Fossil Fuel 化石燃料, 483111 - Deep Sea Freight Transportation , 211111 - Crude Petroleum and Natural Gas Extraction 原油和天然气开采, 221112 - Fossil Fuel 化石燃料, 221112 - Fossil Fuel 化石燃料, Wartsila, Silencer, Catalyst, Valve, Reciprocating Engine, Regulation, Cooling, Heat Recovery, Emissions Control


Practical Methods for Achieving Cooling Tower Water Savings by William Harfst, Harfst and Associates - Hot Topic Hour June 5, 2014

What are the water quality issues? Bill Harfst indicated that with chemical additions the cooling tower cycles of concentration can be increased from the present 3-4 to as many as 10. This greatly reduces water use.

Revision Date:  6/5/2014

Tags:  221112 - Fossil Fuel 化石燃料, 221112 - Fossil Fuel 化石燃料, Harfst and Associates, Cooling Tower, Cooling


DRB Company Profile in the Combined Cycle Journal, October 1, 2013

DRB Industries is a leading supplier of Gas Turbine Inlet Air Filtration, & Cooling Products along with Turnkey Installation. DRB also supplies Cooling Tower Parts & Retrofits, Evaporative Cooling Media and provides Audits and Inspections for plants.

Revision Date:  10/22/2013

Tags:  221112 - Fossil Fuel 化石燃料, DRB Industries, Fogging System, Silencer, Air Inlet House, Cooling Tower, Air Filter, Parts Supplier, Noise, Cooling, Air Intake, Air Filtration, Combined Cycle Journal


ARCTIC Overview by Luke Buntz, Kiewit - Hot Topic Hour March 14, 2013

Luke discussed the ARCTIC (Absorption Refrigeration Cycle Turbine Inlet Conditioning) System.

Revision Date:  3/14/2013

Tags:  221112 - Fossil Fuel 化石燃料, Kiewit Power Engineers, Chiller, Air Intake, Cooling


Inlet Pretreatment for Gas Turbines Webinar - Hot Topic Hour March 14, 2013

Gas turbine performance and maintenance are greatly affected by the cleanliness and physical properties of the incoming air.

Revision Date:  3/14/2013

Tags:  221112 - Fossil Fuel 化石燃料, W. L. Gore, Nederman, TDC Filter, Kiewit Power Engineers, Chiller, HEPA Filter, Air Filter, Cooling, Air Filtration, Air Intake


Dover Combined Cycle (Cricket Valley)-Advanced Power Services

The New York State Public Service Commission has approved a proposed 1,000 MW natural gas-fired power plant. GE will supply 7FA gas turbine technology and the steam turbines for the project. Construction of the power plant could potentially begin in 2014.

Revision Date:  2/28/2013

Tags:  221112 - Fossil Fuel 化石燃料, Cricket Valley Energy Center, Advanced Power, GE, Gas Turbine, Continuous Emissions Monitor, Steam Turbine, Air Cooled Condenser, Project, Monitoring, Cooling, World Power Generation, USA


Electronic treatment removes silica scale in power and semiconductor applications

Silicate has a special form, which is called covalent bond, but most scales have an ionic bond so ion exchangers or Reverse Osmosis Systems are available for removing them. But ion exchanger or RO System can’t remove silicate scale. In addition, silicate scale can’t be dissolved by acid cleaning. Also the magnet treatment developed in the West is subject to restriction in the size of pipe, flow velocity and so on. Furthermore, it is developed to remove scales caused by hard water. Its effect on soft water like in Japan has not been proved. Scalewatcher  ,electronic water treatment equipment, made it possible to remove silicate scale which was impossible by chemical treatment or magnet treatment device within a short time

Revision Date:  1/11/2012

Tags:  221112 - Fossil Fuel 化石燃料, 334413 - Semiconductor and Other Electronic Component Manufacturing , Scalewatcher, Silica Scale, Ultrapure Water, Cooling


A number of U.S power plants used reclaimed water

Nearly all plants built since the 1970s used closed water systems with cooling towers. This article identifies dozens of plants wich are using municipal wastewater for these plants. At the municipal plant sand filters are often used for tertiary treatment prior to transport to the power plant.

Revision Date:  12/5/2011

Tags:  221112 - Fossil Fuel 化石燃料, Xylem, Sand Filter, Cooling Water, Water Reuse, Cooling


Sand and multi media filters are best for cooling tower side stream filtration in big power plants

There is a need for side stream removal of particles 2-30 microns. Sand filters and multi media filters perform well for this application. About 10% of the flow needs to be recirculated. So if all 360,000 MGD were recirculated you would need 36,000 mgd of sand filters.

Revision Date:  12/5/2011

Tags:  221112 - Fossil Fuel 化石燃料, Xylem, Sand Filter, Cooling Water, Cooling


Overview of Microbiological Control & Monitoring in Utility Cooling Systems, presented by K. Anthony Selby, Water Technology Consultants, Inc., at Electric Utility Chemistry Workshop, June 7-9, 2011, Champaign, Illinois

Overview of Microbiological Control & Monitoring In Utility Cooling Systems K. Anthony Selby, Water Technology Consultants, Inc. Cooling water systems in electric utility plants face challenges related to corrosion, mineral scale deposition, microbiological fouling, and suspended solids accumulation. Of these challenges, microbiological control is a primary issue because it can impact the others. In addition to a direct impact on heat transfer, microbiological growth can influence corrosion, trigger mineral scale formation, and accelerate suspended solids accumulation. This overview will discuss the common methods of microbiological control in power plants as well as discussing some emerging technologies. It will also emphasize the importance of monitoring the effectiveness of microbiological control and discuss current monitoring methodology.

Revision Date:  4/14/2011

Tags:  221112 - Fossil Fuel 化石燃料, Water Technology Consultants, Monitoring, Cooling, USA


Fundamentals of Cooling Tower Heat Transfer, presented by Brad Buecker, Kiewit Power Engineers, at Electric Utility Chemistry Workshop, June 7-9, 2011, Champaign, Illinois

Fundamentals of Cooling Tower Heat Transfer Brad Buecker, Kiewit Power Engineers Many power plants and other industrial facilities utilize open recirculating cooling systems equipped with cooling towers for heat transfer from condensers and auxiliary heat exchangers. Cooling towers commonly sit well away from the main plant, and it is often possible to forget about them until something goes awry. This talk outlines the fundamentals of heat transfer in a cooling tower and important issues for maximizing heat exchange.

Revision Date:  4/14/2011

Tags:  221112 - Fossil Fuel 化石燃料, Kiewit Power Engineers, Cooling Tower, Cooling, USA


Development and Application of Phosphorus Free Cooling Water Treatment Technology, presented by Raymond Post, Helen Cerra, and Richard Tribble, ChemTreat, Inc., at Electric Utility Chemistry Workshop, June 7-9, 2011, Champaign, Illinois

Development and Application of Phosphorus Free Cooling Water Treatment Technology Raymond M. Post, Helen R. Cerra, and Richard H. Tribble, ChemTreat, Inc. Organic and inorganic phosphates are key components in cooling water treatment technology. According to the USEPA, nutrient pollution from phosphorus (and nitrogen) is one of the top three causes of impairment of US waters. At least 25 states have enacted some numeric criteria for nutrient discharge. This paper briefly discusses the status of emerging phosphorus discharge regulations and reports on the development of completely phosphorus-free cooling water treatment programs.

Revision Date:  4/14/2011

Tags:  221112 - Fossil Fuel 化石燃料, ChemTreat, Treatment Chemical, Cooling, USA


Sustainability and Filtration - InterWEBview™ with Barry Kellar of Freudenberg Filtration Technologies

Chillers using waste heat can reduce gas turbine fuel consumption per MW while boosting output. Barry Kellar, President of Freudenberg Filtration - North America, was the speaker in a recorded McIlvaine InterWEBview on “Sustainability.” Part of this presentation is devoted to the Villedon eee.sy or energy efficiency enhancement system. Fruedenberg not only furnishes the gas turbine inlet filters but also the cooling of the air entering the turbine based on vapor absorption technology. Waste heat from the system is used as the energy source, so capacity increases of up to 22 percent are achieved without parasitic power consumption. Barry was one of the keynote speakers at Filtration 2010 in Philadelphia. Freudenberg was one of the exhibitors along with a number of other companies familiar to the power industry.

Revision Date:  12/17/2010

Tags:  221112 - Fossil Fuel 化石燃料, Freudenberg Filtration Technologies, Air Filter, Chiller, Energy Efficiency, Cooling, Air Intake, Air Filtration


Sustainability and Filtration 2010 - Presentation Barry Kellar of Fruedenberg Filtration Technologies

Barry Kellar, President of Freudenberg Filtration - North America, was a key note speaker on “Sustainability” at Filtration 2010 in Philadelphia. Part of this presentation is devoted to the Villedon eee.sy or energy efficiency enhancement system. Fruedenberg not only furnishes the gas turbine inlet filters but also the cooling of the air entering the turbine based on vapor absorption technology. Waste heat from the system is used as the energy source, so capacity increases of up to 22 percent are achieved without parasitic power consumption.

Revision Date:  12/1/2010