Internal Data Search by Person

Data Search on:

Sorbent Traps vs. Mercury CEMS Webinar - Hot Topic Hour May 8, 2014

The Hot Topic Hour yesterday included an extensive and friendly debate over the results of sorbent traps and mercury CEMS. The differences of opinion were about gaseous mercury measurement.

Revision Date:  5/8/2014

Tags:  221112 - Fossil Fuel 化石燃料, Durag, Ohio Lumex, Cooper Environmental, Andover Technology Partners, Carbonxt, Sorbent Trap, Multi-metal, CEMS, Mercury


Mercury CEMS and Sorbent Traps Measurements vary because of Particulate Mercury by Jim Staudt of Andover Technology Partners - Hot Topic Hour May 8, 2014

Jim provided the following comparison between CEMS and Sorbent Traps - Method 30B includes HgP, which results in overestimation of gaseous Hg that may be significant at MATS Hg levels but not enough to impact RATA pass or fail  Differences in HgT up to about 0.50µg/Nm3 (typically less, but sometimes more) may be explained by HgP when controlling Hg with ACI and/or Br. Will vary somewhat by coal Hg levels, PM emissions, ACI injection, etc.  Bromine “interference” should not be a concern except possibly under extremely high furnace Br injection rates and is not a concern for brominated activated carbon.

Revision Date:  5/8/2014

Tags:  221112 - Fossil Fuel 化石燃料, Andover Technology Partners, Sorbent Trap, Mercury CEMS


Measuring Ammonia from SCR or SNCR Systems by James Staudt, Andover Technology Partners - Hot Topic Hour April 17, 2014

There is a comparison of NOx differential, UV photometry, TDL and IR as options for NH3 measurement. Successful control of SNCR and TDL is chronicled.

Revision Date:  4/17/2014

Tags:  221112 - Fossil Fuel 化石燃料, 221112 - Fossil Fuel 化石燃料, Andover Technology Partners, Continuous Emissions Monitor, Analyzer - TDL, Analyzer - Nox, Analyzer - NH3, SNCR, Ammonia Slip, Nox Monitoring, Monitoring, Ammonia Monitoring


Measuring Ammonia Slip from Post Combustion NOx Reduction Systems

In many facilities there may be room for process improvement that could reduce operating costs or provide revenue enhancement opportunities. Operating SNCR or SCR technology closer to its limit offers these benefits but increases the risk of high ammonia slip. The risk could be abated with the use of ammonia monitoring technology. But, except for gas-fired plants, continuous ammonia slip monitoring technologies have not been available at a practical price to facilitate these cost-saving or revenue enhancing improvements. Conditions that exist in high dust, high temperature, high NOx and/or high SO2 environments make most analyzer methods of continuously measuring ammonia unsuitable for application to coal plants. An overview of the technologies available for measuring ammonia in the high dust region downstream of a Nox reduction system and the status of their development is provided.

Revision Date:  4/14/2014

Tags:  221112 - Fossil Fuel 化石燃料, 221112 - Fossil Fuel 化石燃料, Andover Technology Partners, SNCR, SCR, Analyzer - TDL, Analyzer - NH3, Ammonia Slip, Monitoring, Ammonia Monitoring


Optimization of Constellation Energy’s SNCR System at Crane Units 1 and 2 Using Continuous Ammonia Measurement

Constellation Energy installed SNCR systems at the CP Crane Station, units 1 and 2. These SNCR systems use continuous ammonia slip analyzers that work on the principle of tunable diode laser (TDL) spectroscopy and provide continuous, real-time indication of ammonia slip in the duct. These analyzers facilitated optimization of the SNCR system to avoid high ammonia slip transients that are the principal contributors to downstream problems normally associated with ammonia slip.

Revision Date:  4/14/2014

Tags:  221112 - Fossil Fuel 化石燃料, 221112 - Fossil Fuel 化石燃料, Constellation Energy, Tourgee & Associates, Andover Technology Partners, Analyzer - NH3, SNCR, Analyzer - TDL, Ammonia Slip, Monitoring, Ammonia Monitoring, USA


GHG Compliance Strategies, Reduction Technologies and Measurement Webinar - Presenter Bios

 

Revision Date:  7/25/2013

Tags:  221112 - Fossil Fuel 化石燃料, World Resources Institute, Sidley Austin LLP, Sanford Cohen & Associates, Andover Technology Partners


GHG Compliance Strategies, Reduction Technologies and Measurement - Hot Topic Hour July 25, 2013

 

Revision Date:  7/25/2013

Tags:  221112 - Fossil Fuel 化石燃料, Andover Technology Partners, Sidley Austin LLP, Sanford Cohen & Associates, World Resources Institute, Greenhouse Gas, Regulation


Greenhouse Gas Mitigation from the Power and Portland Cement Sectors by James E. Staudt, Andover Technology Partners - Hot Topic Hour July 25, 2013

Reviewed the status of GHG regulations in the U.S. and various technologies for mitigating GHG emissions in the power and cement sectors.

Revision Date:  7/25/2013

Tags:  221112 - Fossil Fuel 化石燃料, 327310 - Cement Manufacturing 水泥生产, Andover Technology Partners, Greenhouse Gas, Regulation


Greenhouse Gas Mitigation from Power Plants by James Staudt - Hot Topic Hour March 31, 2011

Jim Staudt PhD, President of Andover Technology Partners, provided an overview of ongoing activities in the greenhouse gas mitigation area with particular focus on the U.S. EPA’s Greenhouse Gas Mitigation Options Database. It is designed to help developers, suppliers, consultants and the operators select the best options.

Revision Date:  3/31/2011

Tags:  221112 - Fossil Fuel 化石燃料, Andover Technology Partners, CO2