Internal Data Search by Company/Division Name

Data Search on:

The titles below have an association with your requested company name

Yokogawa Supplies Integrated Control System for Power Plant at Chinese Petrochemical Complex

The Dushanzi Refinery & Petrochemical Complex in northwestern China processes crude oil and produces ethylene. The utility plant for the complex provides steam, electricity and water. Power is generated by five coal-fired circulating fluidized bed (CFB) boilers, four of which operate at a time. Yokogawa Electric Co. supplied the integrated control system to manage boiler efficiency, coal consumption, rate of electricity generation and other parameters.

Revision Date:  1/8/2013

Tags:  221112 - Fossil Fuel 化石燃料, PetroChina, Yokogawa Electric, Integrated Control System, CFB Boiler, China


Yokogawa Supplies Integrated Control System for Power Plant Upgrade in Australia

The 180-MW Morwell Power Station in Australia was built in the 1950s. As part of an extensive modernization program in 2008, Yokogawa Electric Co. was selected to supply an integrated control system which optimizes the combustion of brown coal and reduces emissions.

Revision Date:  1/8/2013

Tags:  221112 - Fossil Fuel 化石燃料, Yokogawa Electric, Integrated Control System, Australia


Yokogawa Supplies System to Control Transfer of Heat and CO2 from Power Plant to Greenhouses in the Netherlands

The gas-fired ROCA Power Station in The Netherlands captures CO2 from the flue gas and transports heat and captured CO2 through a pipeline network to over 100 nearby greenhouses. Yokogawa Electric Co. installed monitors and remote controllers in each greenhouse, along with a central control system, to regulate the transfer of heat and CO2.

Revision Date:  1/8/2013

Tags:  221112 - Fossil Fuel 化石燃料, Eneco, Yokogawa Electric, Integrated Control System, CO2 Monitor, Air Monitoring, Netherlands


Yokogawa Supplies Integrated Control System to Ensure Reliable Power Production at Vietnamese Power Plant

Pha Lai 2 is a 600-MW coal-fired power station in Vietnam that supplies close to half of the electricity for Hanoi. Stable and reliable operation of the plant are critical. Yokogawa Electric Co. was selected to supply an integrated control system for the plant, which includes a burner management system and a coal handling system.

Revision Date:  1/8/2013

Tags:  221112 - Fossil Fuel 化石燃料, Pha Lai Thermo Power, Yokogawa Electric, Integrated Control System, Vietnam


Yokogawa Supplies Combustion Optimization System and Flue Gas Monitors for Biomass Plant

The 22.5 MW Pichit Biopower Plant in Thailand uses ground rice husks as its fuel. Yokogawa Electric Co. supplied an integrated control system that manages the complex sequence of effectively burning the biomass. The system includes zirconium oxygen analyzers to optimize the combustion process. Yokogawa also provided a number of flue gas monitors to measure CO, CO2, O2, NOx and SOx concentrations. All water used in the plant is analyzed by pH and conductivity meters.

Revision Date:  1/8/2013

Tags:  221117 - Biomass Power , Yokogawa Electric, A.T. Biopower, pH Meter, SO2 CEMS, NOx CEMS, O2 CEMS, CO CEMS, CO2 Monitor, Oxygen Analyzer, Thailand


Yokogawa Supplies Integrated Control System for 50-Year Old Power Plant in Missouri

The 50-year old James River Power Plant in Springfield, Missouri, consists of five coal-fired units with a total capacity of 253-MW. Yokogawa Electric Co. supplied an integrated control system for the plant that combines two control rooms and five separate control systems into one integrated system. The plant modernization project also included the installation of ultra-low-NOx burners and overfire-air to reduce NOx emissions.

Revision Date:  1/8/2013

Tags:  221112 - Fossil Fuel 化石燃料, Yokogawa Electric, City Utilities of Springfield, Low NOx Burner, Integrated Control System, USA


Yokogawa Supplies Control System to Ensure Smooth Supply of Power from Wind Farm

The Rokkasho Wind Farm in Japan uses large-capacity sodium sulfur (NAS) batteries to store electricity for supply to the national power grid. Yokogawa Electric Co. supplied a monitoring and control system which monitors each battery and each windmill, and calculates power output patterns to ensure a stable supply of power to the grid.

Revision Date:  1/8/2013

Tags:  221114 - Wind Power , Yokogawa Electric, Japan Wind Development, Integrated Control System, Japan


Yokogawa Wins Control System Order for First IGCC Power Plant in Korea

Yokogawa Electric Co. has been awarded a contract by Doosan Heavy Industries to supply a control system for the first integrated gasification combined cycle (IGCC) power plant in South Korea. The 300-MW facility is being constructed by Korea Electric Power Corp. (KEPCO) in Taean, South Korea, and is expected to be completed by the end of 2015.

Revision Date:  1/8/2013

Tags:  221112 - Fossil Fuel 化石燃料, Yokogawa Electric, Korea Electric Power Co. (KEPCO), IGCC, Integrated Control System, South Korea


Yokogawa Supplies Integrated Control System for Waste-to-Energy Plant in the UK

Lakeside EFW Ltd. operates an EFW (energy from waste) facility near London that burns household and municipal waste to produce electricity and exports at least 34-MW per hour to the national grid. Yokogawa Electric Co. was selected to supply the integrated control system to automate control of the facility’s boilers, burners and balance of plant facilities.

Revision Date:  1/8/2013

Tags:  221118 - Other Electric Power , Yokogawa Electric, Lakeside EFW, Integrated Control System, Municipal Waste Incineration, UK


NH3 Slip Measurement by Donald Wyatt, Yokogawa – Youtube Presentation

Overview of tunable diode lasers for measuring ammonia slip and other gases.

Revision Date:  2/25/2013

Tags:  221112 - Fossil Fuel 化石燃料, 221112 - Fossil Fuel 化石燃料, Yokogawa Electric, Analyzer - NH3, IR Laser Spectroscopy, SCR, SNCR, Ammonia Slip, Monitoring, Nox Control


Article by McIlvaine on Gas Turbine Emissions in Air Polluton Control Magazine

In this article, Bob McIlvaine talks about Gas Turbine Emissions and Controls, focusing on intake air filters and NH3 slip monitors.

Revision Date:  3/8/2013

Tags:  221112 - Fossil Fuel 化石燃料, Yokogawa Electric, Nederman, SICK MAIHAK, Analyzer - TDL, Analyzer - NH3, SCR, Air Filter, Ammonia Slip, Air Filtration, Air Intake, Air Pollution Control, Monitoring, Air Pollution Control


Yokogawa at Electric Power 2013

 

Revision Date:  5/24/2013

Tags:  221112 - Fossil Fuel 化石燃料, Yokogawa Electric, Instrument, Meter, SCR, SNCR, NH3 Monitor, IR Laser Spectroscopy, Testing, USA


NH3 Slip Measurement by Donald Wyatt, Yokogawa - Hot Topic Hour February 14, 2013

History of tunable diode lasers for measuring ammonia slip and other gases.

Revision Date:  2/14/2013

Tags:  221112 - Fossil Fuel 化石燃料, 221112 - Fossil Fuel 化石燃料, Yokogawa Electric, SNCR, IR Laser Spectroscopy, SCR, Analyzer - NH3, Ammonia Slip, Air Pollution Control, Monitoring


Boiler Feedwater Pump Efficiency Optimization - Yokogawa

The optimization of boiler feedwaer operations depends on controlling feedwater and drum pressure. The Yokogawa Dpharp can measure pressures up to 2000 psi and can measure across a range of pressures with high accuracy. Significant energy and maintenance reduction is achieved with optimization of pressure differential.

Revision Date:  9/17/2014

Tags:  221112 - Fossil Fuel 化石燃料, Yokogawa Electric, Boiler Feedwater Pump, Efficiency, Optimization


Yokogawa wirless system for monitoring rotating equipment

Yokogawa has created a sensor and wireless transmitter system designed specifically for continuous monitoring of the rotating equipment commonly used in process manufacturing facilities . The system is designed for easy installation on a wide variety of equipment. The piezoelectric acceleration sensor is compact and easy to install near the device’s bearings . A cable connects it to a wireless communication module, which can be mounted wherever it is convenient, and where it can be clear of obstructions able to interfere with its signal propagation. The complete system is self-powered using a battery in the communication module. With a one-minute data update rate, one set of batteries can run for up to 10 years. The data is sent via the wireless network to the system gateway. If other ISA100 Wireless field devices are already in use in the facility, the vibration monitors can become part of the same network, communicating with the gateway just like any other communication module or sensor. Data from the units installed throughout the plant can be directed to a control or monitoring system to inform operators and maintenance personnel as conditions change with the equipment being monitored.

Revision Date:  3/23/2018

Tags:  Yokogawa Electric, Pump, Monitoring