Industrial Boiler MACT Rule - Impact and Control Options for Mercury and Dioxins/Furans by Richard Miller, ADA-ES - Hot Topic Hour November 19, 2010

Richard (Rich) Miller, Vice-President of Business Development for Utility Systems at ADA Environmental Solutions (ADA-ES), showed timelines which dictate that boiler operators start mercury testing soon. There are lots of unknowns due to the wide variety of fuels and boiler configurations. With the potential of large carbon needs by the utility and cement industries, supply could be an issue. Mercury reduction guarantees are going to be tough to provide since the need is a mass emission level and not a percent removal. Furthermore the 0.2 lbs/TBtu limit for biomass boilers will be difficult to measure as well as guarantee.

Revision Date:  11/19/2010

Tags:  221112 - Fossil Fuel 化石燃料, ADA-ES, Activated Carbon, MACT, Industrial Boiler


Improving ESP Performance Webinar - Hot Topic Hour January 20, 2010

ESP Performance Improvement can be Substantial - Hot Topic Conclusion on January 20 There has been lots of focus on replacing ESPs with baghouses to meet upcoming regulations. The speakers in the Hot Topic Hour yesterday said there is an alternative. You can upgrade existing ESPs and achieve results which may satisfy future requirements. Dr. Yougen Kong, P.E., Technical Development Manager at Solvay Chemicals, Inc., told the attendees that “there is a better alternative to SO3 for conditioning electrostatic precipitators.” Trona addition system is simple and its capital cost is much lower than that of a SO3 production and injection system. Trona is relatively inexpensive and can be injected in several places. Mick Chambers, Southern Environmental, Inc, said that you can upgrade your ESP and with halogen-based additives in the coal, you can meet the particulate and mercury regulations. He showed that the SCA of recent installations has been relatively low and yet the performance high. So the footprint of a retrofit does not have to be large. When asked about the wet ESP using a fabric for the collection plate, Mick said that it is a good option and successful on industrial boilers and process applications. We were sorry to learn that John Caine passed away in a tractor accident last September. John had represented SEI in several of our previous Hot Topic Hours and has long been a contributor to the industry. Steve Jaasund, Manager Geoenergy Division A. H. Lundberg Associates, made a case for adding a wet ESP after the FGD system to meet the upcoming MACT regulations. In the discussion period it was speculated that the new mass monitoring requirements would make it more difficult for dry ESPs to meet emission limits. The wet ESP will eliminate the exceedance spikes associated with a stand-alone dry ESP. Paul Leanza of Pollution Control Services, Inc. indicated that many utilities have the opportunity to greatly improve performance of their existing precipitators. He indicated that 50 percent of the emissions occur during rapping (rapping reentrainment). These particles are relatively large and do not cause opacity spikes proportional to the mass increase. It was speculated that with mass monitoring this phenomenon will be an unpleasant surprise. Emissions will be higher with mass monitors than they were thought to be with opacity monitors and periodic stack testing. Ron Landreth of Albemarle was pleased to find that their brominated PAC actually improves precipitator performance whereas the non-brominated PAC may add to emissions. So it is worth considering brominated PAC to capture mercury and reduce particulate. Jean Bustard of ADA-ES (ADA Environmental Solutions LLC) related experience with a proprietary conditioning chemical which has performed well and does not impact mercury capture with PAC. The company offers another approach to conditioning hot side precipitators.

Revision Date:  1/20/2011

Tags:  221112 - Fossil Fuel 化石燃料, A.H. Lundberg Associates, Southern Environmental, Pollution Control Services, Albemarle, ADA-ES, Solvay Chemicals, Dry Sorbent Injection, Electrostatic Precipitator, Mercury


Modifying Ash Resistivity and Improving ACI Performance for Mercury Control with Liquid Flue Gas Conditioning by Jean Bustard, ADA-ES - Hot Topic Hour January 20, 2011

Conditioning systems and additives.

Revision Date:  1/20/2011

Tags:  221112 - Fossil Fuel 化石燃料, ADA-ES, Dry Sorbent Injection


Mercury Measurement and Control - Webinar - Hot Topic Hour April 12, 2012

Current monitoring and control of mercury from coal-fired power plants.

Revision Date:  4/12/2012

Tags:  221112 - Fossil Fuel 化石燃料, ADA-ES, Thermo Fisher, Norit, Albemarle, Shaw Group, Sampling Line, Bromine, Activated Carbon, Mercury Monitor, Dry Sorbent Injection, Air Quality, Mercury, Utility MACT, Air Pollution Control


Overview of MATS for Existing & New Plants by Connie Senior, ADA - Hot Topic Hour April 12, 2012.

Connie reviewed the regulations and the ability of activated carbon to meet the requirements.

Revision Date:  4/12/2012

Tags:  221112 - Fossil Fuel 化石燃料, ADA-ES, Dry Sorbent Injection, Mercury, Utility MACT, Air Quality, Air Pollution Control


Mercury Measurement and Control - Part 1, Webinar - Hot Topic Hour March 28, 2013

MATS Compliance

Revision Date:  3/28/2013

Tags:  327310 - Cement Manufacturing 水泥生产, 221112 - Fossil Fuel 化石燃料, ADA-ES, CB&I, CleanAir Engineering, Andover Technology Partners, Activated Carbon, Sorbent Trap, Bromine, Mercury Monitoring, Mercury


Mercury Control from Coal to Stack by Sharon Sjostrom, ADA-ES - Hot Topic Hour March 28, 2013

Sharon presented an overview of important considerations for achieving MATS compliance for mercury.

Revision Date:  3/28/2013

Tags:  221112 - Fossil Fuel 化石燃料, 327310 - Cement Manufacturing 水泥生产, ADA-ES, Activated Carbon, Mercury Monitoring, Mercury