How to Design, Retrofit Drum-type HRSGs to Cycle, Start Faster
Fast start and fast ramp of HRSGs in necessary in order to back up renewables when the wind stops or clouds appear. Fast starts/fast ramps also reduce the total emissions during a start, cut startup costs, and enable the plant to achieve full-load revenues faster. This article summarizes a presentation regarding the design and retrofit of HRSGs in order to optimize fast starts and fast ramps.
Revision Date: 6/3/2015
Tags: 221112 - Fossil Fuel 化石燃料, Vogt Power International, Heat Recovery Steam Generator, Optimization, Heat Recovery, Fast Start, Combined Cycle Journal