Main Feed Water and Booster Pumps for Coal- and Oil-fired

Feed Water Pumps (FWP) pump the feed water from the de-aerator through the HP heaters to the boiler. The major characteristic of FWP is their high differential head. In medium to large size coal- and oil-fired power plants, the main FWP are horizontal barrel type while booster pumps are horizontal single stage double suction type. In small coal and oil captive power plants, the main FWP could be also horizontal ring section or axially split type and the booster pumps horizontaly single stage end suction type


Sulzer provides the following barrel casing as well as ring section and axially split pumps as main feed water pumps for coal- and oil-fired power plants:

  HPT GSG CP
Capacities   Up to 4,000 m3/h /
13,800 USgpm
Up to 900 m3/h /
4,600 USgpm
Up to 1,000 m3/h /
4,400 USgpm
Heads Up to 4,200 m /
13,800 ft
Up to 2,600 m /
10,000 ft
Up to 7,000 m /
23,000 ft
Pressures   Up to 450 bar /
6350 psi
Up to 300 bar /
4,500 psi
Up to 425 bar /
6,250 psi
Temperatures Up to 220°C / 430°F Up to 425°C / 800°F Up to 425°C / 800°F

  ME MD  MSD
Capacities   Up to 1,750 m3/h / 7,700 USgpm Up to 1,000 m3/h / 5,000 USgpm Up to 3,200 m3/h / 14,000 USgpm
Heads Up to 4,000 m /
13,120 ft
Up to 2,400 m /
8,200 ft
Up to 2,900 m /
9,500 ft
Pressures   Up to 430 bar /
6,240 psi
Up to 50 bar / 
725 psi
Up to 300 bar /
4,400 psi
Temperatures Up to 220°C / 430°F Up to 210°C / 410°F Up to 200°C / 400°F

 


Sulzer provides the following single stage pumps as booster pumps for coal- and oil-fired power plants:

 

  HZB ZE 
Capacities   Up to 5,500 m3/h /
29,000 USgpm
Up to 2,600 m3/h /
11,440 USgpm
Heads Up to 340 m / 1,115 ft Up to 300 m / 1,000 ft
Pressures   Up to 48 bar / 700 psi Up to 100 bar / 1,450 psi
Temperatures Up to 220°C / 428°F Up to 425°C / 800°F