This is the pump peculiar to the forced circulation type boiler. This pump is
necessary for protection of the cooling pipe of the furnace. It circulates water
in the cooling pipe of the furnace when starting the operation and at low load
and always maintains the flow in the pipe approximately at a fixed speed.
|
This is the pump for sending high pressure and high temperature fluid to the
boiler. The types vary depending upon the pressure. The single casing type is
used for the combined cycle, the subcritical steam power generation, etc. In the
case of the pump of the ring section type, suction, intermediate and discharge
casings are joined tightly with bolts and compose the pump casing.
|
The casing is split in the upper and lower parts and composes the pump casing.
Fabrication and disassembly is easy but this type is inferior to other types
with respect to the capacity of pressure resistance.
|
This is the multi-stage pump having the double casing, the inner casing
contained in the outer casing. Among various boiler feed water pumps, this pump
is adopted for high pressure and high temperature application as in the
subcritial steam power generation. The double casing is also called "barrel
type". As in the case of the single casing, there are differences in the way of
splitting the inner casing, and special features are the same.
|
This is the multi-stage pump having the double casing, the inner casing
contained in the outer casing. Among various boiler feed water pumps, this pump
is adopted for high pressure and high temperature application as in the
subcritial steam power generation. The double casing is also called "barrel
type". As in the case of the single casing, there are differences in the way of
splitting the inner casing, and special features are the same.
|
This is the pump to send cooling water to the condenser. Depending upon the
water intake source, the vertical type is usually used when taking water
directly from sea, and the horizontal type is commonly used when taking water
from the cooling tower. The type having the controllable movable impeller is
called the variable pitch vane type.
|
The fixed type impeller as shown to the left is called the fixed pitch vane
type.
|
This is the pump for pumping condensate from the condenser. This is the
important pump that should be regarded, so to speak, as the starting point of
the main cycle of the power plant.